Calibration helps fix mark sense scanning, allows you to darken images, and can get rid of unwanted lines through text. Calibration should be done after the scanner is cleaned (for instructions on cleaning your scanner click here). TIP: It is a good idea to do this about once a week, as blobs of build up on the scanner glass.
- Exit Arkle epos (as you need to run EngBench, which can’t operate when Arkle has the scanner in operation).
- Run EngBench (try running as administrator). There should be a shortcut or your desktop (otherwise navigate to C:\Program Files\bizTech Software\Arkle – ePos\ where you will find it.
-
-
- Click Cal button (to initiate calibration)
- Insert a blank sheet of A4 into scanner (leave it in scanner, it won’t automatically scan through).
- Click OK (the scanner will now start processing the blank A4)
- The scanner will process the blank A4 by repeatedly pulling the paper in and out, this is normal.
- Once this has completed, scan a few test slips and modify the light setting and gamma, until you are happy with scanned image.
- Click OK, to save the new settings, and log back into Arkle and test the scanner there. If settings do not appear to have saved, you may not have run as administrator or have correct permissions to save files to the Arkle ePos folder.